Permit: T07CM00613

Parcel: 12711081A


Addresses:

5952 E SPEEDWAY BL


Inspection Status: Not ready for Inspection

Inspection History: BUILDING - PROGRESS

Permit Number - T07CM00613

Inspection Description - BUILDING - PROGRESS

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
02/27/2007 BUILDING - PROGRESS Not ready for Inspection SITE INVESTIGATION FOR RECCOMENDATIONS ON ISSUING OF PERMIT FOR CofO FOLLOW:
1) THREE STRUCTURES ON SITE (MASONRY OFFICE, WOOD/HT SHOP, AND STEEL PARKING CANOPY) MAY BE REVIEWED AS SINGLE VB BUILDING WITH 3 SUITES.
2) AS BUILT FLOOR PLAN MAY BE ACCEPTED FOR ALL THREE STRUCTURES.
3) OWNER NEEDS TO HAVE LICENSED ELECTRICIAN ENSURE EXISTING ELECTRIC IS IN GOOD REPAIR AND LABEL ALL CIRCUITS.
4) ALL PLUMBING FACILITIES, WALKING SURFACES, DOORS, WINDOWS, ETC TO BE IN GOOD REPAIR AND FUNCTIONING PROPERLY.
5) MASONRY SITE WALL ON SOUTH PROPERTY LINE IS SUITABLE AS FIRE BARRIER FOR STEEL CANOPY BUT 5' SETBACKS ON EAST AND WEST WILL HAVE TO COMPLY WITH TABLE 602 OF 2003 IBC.
6) MASONRY CONSTRUCTION ON EAST SIDE OF NORTH BUILDING IS SUITABLE AS FIRE WALL AND MEETS TABLE 602 REQUIREMENTS.
7) 10' SETBACK FROM EAST PROPERTY LINE FOR BUILDING 2 IS SUITABLE FOR NON-RATED CONSTRUCTION PER TABLE 602.