Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 06/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1. PLAN CALLS FOR 6X12 BEAM 3X10 2. NEED A FTG. FOR INTER. POST COL 3. 2X6 HEADER WEST WALL OPENING 4. NAIL OFF SIDING (6" EDGE) X (12" IN THE FIELD) 5. NEED POST BASES 6. FINISH ELEC. ALL FOOTINGS OK EXCEPT INTERIOR POST NOTE: CHECK OVERHANG EAST WALL |