| 04/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PERIMETER OF SOUTHWEST SHEARWALL 2) RSP4'S NEEDED SOUTHWEST MAIN FLOOR CORNER 3) MINIMUM 2 ANCHOR BOLTS ON BOTTOM PLATES OF FRONT COLUMNS 4) RSP4 NEEDED FRONT ENTRANCE GARAGE WALL 5) HTT16 NEEDED ON HOUSE/GARAGE SHEARWALL NEXT TO GARAGE SERVICE DOOR 6) COIL STRAP BEAM TO FRONT COLUMNS 7) KING STUD MISSING NORTH SIDE FRONT ENTRANCE 8) CARRY BEARING TO FOUNDATION UNDER A13G GIRDER |
|
| 03/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled |