Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00545
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2007 | FRAMING | Approved | IVRS - Inspection :* | |
08/09/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PUMP UP SOLAR WATER HEATER LINE FOR PRESSURE TEST |
|
08/08/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PRESSURE TEST SOLAR SYSTEM |
|
07/31/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED APPROVED PLAN FOR WINDOW CHANGE 2) INSTALL NUT ON H/D 3) DWV TEST OK 4) PRESSURE TEST ON SOLAR NEEDS TO BE 50 POUNDS MINIMUM |
|
07/30/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIGHTEN NUT ON H/D'S NORTH WALL L/R 2) WINDOWS MOVED ON 2ND FLOOR PER ENGINEERS DRAWINGS 3) NEED C OF T PLAN CHECK APPROVAL 4) SOLAR TEST 28 # 5) LEAK IN DWV L/R CEILING 6) FLAT VENT WYE L/R CEILING LOWER THAN DRAIN |
|
07/26/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEAK AT MAIN FLOOR DWV 2) PROVIDE TEST ON ALL COPPER LINES 3) MISSING POST UNDER BEAMS/NAIL OF ALL HARDWARE 4) MISSING BLOCKING #2 SHEARWALLS 5) NEED TO REVISE PLANS TO SHOW ALL CHANGES 6) INCLUDING MOVING WINDOWS WITH CITY APPROVAL |
|
07/24/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |