Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/10/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS FROM PRIOR INSPECTION HAVE NOT BEEN CORRECTED 4/3/07 |
|
04/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. EDGE BLOCKING NEEDS TO BE NAILED 2. SHEAR TRANSFER WALL CONNECTION TO ROOF NEEDS 8D NAILS. 3. TOP OUT AT GARAGE NEEDS ROOF NAILING 4. SHEAR WALL CONNECTION TO TRUSS CALCS FOR 16D NAIL STAGGERED 4" O.C |