Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM00531
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CLOSET FLANGES OK |
|
09/13/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RDS W/TEST OK DWV OK HAMMER ARRESTORS OK SECURE TRAP PRIMERS TO ASSURE ALIGNMENT INSULATE 8' OF PIPING TO AND FROM WH MAINTAIN ACCESS TO ABV CEILING MV OK TO COVER WALLS |
|
09/12/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - SUPPORT ON PLASTIC PIPING AT CHANGES OF DIRECTION AND BRANCH CONNECTIONS - SWEEPS REQUIRED ON VERT TO HORIZ AND HORIZ TO HORIZONTAL CHANGES OF DIRECTION - TEST ON DWV OK - INSTALL HAMMER ARRESTORS PER PLAN - FLANGES REQUIRED TO BE ABV FINISHED FLOOR AND SECURED |