Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00531

Parcel: 134244350


Addresses:

1111 S WILMOT RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM00531

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
RECEIVED OK FOR ABS & DWV AND PVC SCH 40 YARD WATER
08/24/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE CITY APPROVED PLAN WITH PLAN CHECK STAMP OF SITE SEWER & WATER
2. PROVIDE STAMPED LETTER FROM ENGINEER FOR OK TO USE ABS SCH40 DWV & SEWER PIPING IN PLACE OF CAST IRON OR PVC. OK INSTALL PER PLAN
3. PROVIDE STAMPED LETTER FROM ENGINEER GIVING OK
FOR PVC SCH 40 YARD WATER IN PLACE OF CPVC SCH 80
OR INSTALL PER PLAN

WATER TEST FROM EXISTING CONNECTION FOR SEWER BACK THRU BUILDING SANITARY & GREASE WASTE TO C.O HEIGHT

1. SHALL PROVIDE LONG RADIUS DRAINAGE FITTINGS FOR VENTS BELOW FLOOD RIM OF FIXTURE
2. SHALL PROVIDE CORRECT VENT FOR INTERCEPTOR