Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T07CM00531
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* RECEIVED OK FOR ABS & DWV AND PVC SCH 40 YARD WATER |
|
08/24/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PROVIDE CITY APPROVED PLAN WITH PLAN CHECK STAMP OF SITE SEWER & WATER 2. PROVIDE STAMPED LETTER FROM ENGINEER FOR OK TO USE ABS SCH40 DWV & SEWER PIPING IN PLACE OF CAST IRON OR PVC. OK INSTALL PER PLAN 3. PROVIDE STAMPED LETTER FROM ENGINEER GIVING OK FOR PVC SCH 40 YARD WATER IN PLACE OF CPVC SCH 80 OR INSTALL PER PLAN WATER TEST FROM EXISTING CONNECTION FOR SEWER BACK THRU BUILDING SANITARY & GREASE WASTE TO C.O HEIGHT 1. SHALL PROVIDE LONG RADIUS DRAINAGE FITTINGS FOR VENTS BELOW FLOOD RIM OF FIXTURE 2. SHALL PROVIDE CORRECT VENT FOR INTERCEPTOR |