Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T07CM00530
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
02/21/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COLUMN FOOTERS NOT PER PLAN 9/SD1 2) NEED TO REMOVE ALL CONCRETE AND START OVER 3) IF PAD IS 12" X 12" YOU NEED A FOOTER 28 X 28 X 12" DEEP AND REBAR ? #4 BAR 12 ON CENTER 3 BARD EACH WAY |
|
02/20/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO APPROVED PLANS ON SITE |