Permit: T07CM00530

Parcel: 140325000


Addresses:

3986 E BIG GAME PL


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T07CM00530

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
02/23/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
02/21/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COLUMN FOOTERS NOT PER PLAN 9/SD1
2) NEED TO REMOVE ALL CONCRETE AND START OVER
3) IF PAD IS 12" X 12" YOU NEED A FOOTER 28 X 28 X 12" DEEP AND REBAR ? #4 BAR 12 ON CENTER 3 BARD EACH WAY
02/20/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO APPROVED PLANS ON SITE