Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00520
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/14/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 4 A35 CLIPS FROM DRAG TRUSS TO TOP PLATE OF SHEARWALL BACK OF GARAGE 2) OVERNOTCHED 2 X 4 STUD EAST GARAGE WALL 3) NAIL PROTECT 10/3 WIRE TOP PLATE UTILITY ROOM 4) INSTALL LIGHT MAIN FLOOR WATER CLOSET ROOM 5) NAIL PROTECTION NEEDED MAIN FLOOR BEDROOM EAST WALL UNDER WINDOW 6) NAIL PROTECT WIRE MAIN FLOOR LIVING ROOM SOUTH OF WATER CONDENSATE 7) NAIL PROTECT SUPPLY LINES TOP PLATE UTILITY ROOM 8) 8-16D NAILS EACH SIDE OF NOTCH IN FHA STRAP IN UTILITY ROOM |