Permit: T07CM00516

Parcel: 141340580

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM00516

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/11/2007 FRAMING Approved IVRS - Inspection :*
07/09/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED BY SUPER
07/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRESTOP DUCT CHASE AT CEILING AT TOP OF STAIRS
2) APPROVED GLUE NEEDED INSIDE OF JOINT OF ABS TO PVC NOT JUST OVER CONNECTION AFTER PUT TOGETHER
06/28/2007 FRAMING Partial Approval IVRS - Inspection :*
1) FRAME AROUND FIREPLACE
2) APPROVED GLUE FOR ABS TO PVC GLUE
3) OK TO INSULATE
06/25/2007 FRAMING Partial Approval IVRS - Inspection :*
1) SHEARBLOCK NAIL
2) HANGER 1890/2365 POUNDS 14-16D'S
3) SEAL PLENIUM
4) FINISH FIRE FRAME
5) ABS-PVC CONNECTION FURNACE FLUE
6) DRYER DUCT OUT OF WALL
06/22/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK AROUND TUB DRAINS IN CEILINGS
2) COMPLETE FIREPLACE INSTALL
3) B-VENT CAN HAVE 1-30 DEGREE SLOPE, REMAINDER MUST BE 45 DEGREE OR MORE
4) SEAL HOLE IN FLOOR IN RETURN AIR PLEMIUM
06/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN NUTS AND WASHERS ON H/D'S
2) FIRE STOP TUBS
3) INSTALL BLOCKING FOR SHEAR IN LOFT
4) COMPLETE WIRING FOR KITCHEN LIGHT AND ENTERTAINMENT AREA
5) SUPPLY LOSING PRESSURE
6) EXTEND WATER B-VENT THRU ROOF AND CEILING
7) MINIMUM SLOPE 30 DEGREE
8) DRYER DUCT MAX LENGTH 2/5 MINUS 5' FOR EACH 90
9) COMPLETE FIREPLACE INSTALLATION
10) COMPLETE RETURN AIR DUCTS