Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00516
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/11/2007 | FRAMING | Approved | IVRS - Inspection :* | |
07/09/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY SUPER |
|
07/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP DUCT CHASE AT CEILING AT TOP OF STAIRS 2) APPROVED GLUE NEEDED INSIDE OF JOINT OF ABS TO PVC NOT JUST OVER CONNECTION AFTER PUT TOGETHER |
|
06/28/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FRAME AROUND FIREPLACE 2) APPROVED GLUE FOR ABS TO PVC GLUE 3) OK TO INSULATE |
|
06/25/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SHEARBLOCK NAIL 2) HANGER 1890/2365 POUNDS 14-16D'S 3) SEAL PLENIUM 4) FINISH FIRE FRAME 5) ABS-PVC CONNECTION FURNACE FLUE 6) DRYER DUCT OUT OF WALL |
|
06/22/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK AROUND TUB DRAINS IN CEILINGS 2) COMPLETE FIREPLACE INSTALL 3) B-VENT CAN HAVE 1-30 DEGREE SLOPE, REMAINDER MUST BE 45 DEGREE OR MORE 4) SEAL HOLE IN FLOOR IN RETURN AIR PLEMIUM |
|
06/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIGHTEN NUTS AND WASHERS ON H/D'S 2) FIRE STOP TUBS 3) INSTALL BLOCKING FOR SHEAR IN LOFT 4) COMPLETE WIRING FOR KITCHEN LIGHT AND ENTERTAINMENT AREA 5) SUPPLY LOSING PRESSURE 6) EXTEND WATER B-VENT THRU ROOF AND CEILING 7) MINIMUM SLOPE 30 DEGREE 8) DRYER DUCT MAX LENGTH 2/5 MINUS 5' FOR EACH 90 9) COMPLETE FIREPLACE INSTALLATION 10) COMPLETE RETURN AIR DUCTS |