Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00509
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) USE 16D IN ALL HTT AND P.A.'S |
|
| 03/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE LAST INSPECTION |
|
| 03/23/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL ALL HORIZONTAL JOINTS AT FRONT SHEAR 2) USE MINIMUM 10 D COMMONS IN HANGERS AT LEDGER 3) MISSED NAILING ON ROOF REAR WEST 4) WRONG NAILS IN H.D.'S AND P.A.'S 5) NO NOTCHING OF GABLE TRUSSES 24" ON HEEL JOINT 6) WRONG HANGERS AT LEDGERS |