Permit: T07CM00507

Parcel: 133092760


Addresses:

2200 N HAYDEN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00507

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/21/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/15/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF SHEATHING AND SIDDING ARE TO BE NAILED OFF 6" ON CENTER ON EDGES AND 12" ON CENTER FIELD
2) BEAMS OVER WINDOWS MUST BE SUPPORTED BOTH ENDS
3) IF WINDOW OPENINGS ARE LARGE THAN PLANNED, NEW BEAM SIZES MUST BE CALCULATED
4) SEVERAL CHANGES WILL BE REQUIRED ON FRAMING
5) NEED MINIMUM 1/8" SPACING ON ROOF PLYWOOD