Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T07CM00498
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/06/2007 | ROOF NAILING | Approved | IVRS - Inspection :* | |
04/03/2007 | ROOF NAILING | Partial Approval | 1. RE-NAIL H.D AT ENTRY -- NAILING MISING 2X4 LOSING STRENGTH VALUE 2. LET IN BRACE WEST WALL NEED 2 NAILS INTO TOP & BOTTOM PLATE - 2 PLCS 3. NEED PROTECTION PLATES AT PLUMBING VENTS 2 PLCS 4. CHECK SHEAR WALL FLOOR PLAN FOR MISSING A.B 5. ROOF OK TO DRY IN -- 2ND FLOOR NAILING NOT COMPLETED |