Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00496
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. RSP4 CLIP - 2ND FLOOR SW CORNER - NEEDS NAILS 2. PROTECTION PLATES ON PLUMBING VENT WEST SIDE AND SOUTH 3 PLCS 3. COIL STRAP AT FRONT ENTRY PORCH BEAM NEEDS MORE NAILS. 4. H.D AT FRONT ENTRY NOT NAILED TO SHEAR PANEL PER DESIGN 5. NEED A.B BOLT AT GARAGE WEST WALL - WHERE PLATE IS SPLICED 6. A.BOLTS MISSING ON SHEAR WALL PANEL PER SHEAR WALL PLAN. |