Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00494
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* PLUMBING VENT AT MASTER BATH, HAS A NAIL IN IT. WILL CHECK AT INTERMEDIATE FOR FIX |
|
04/12/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM #2 & #4 MASTER BATH VENT HAS A NAIL IN IT 2) 3RD TIME OUT ON SAME INSPECTION |
|
04/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1, 2, 3, 4, 5 & 7 2) NO PLANS ON SITE TO CHECK #6 |
|
04/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER SUPERINTENDENT |
|
04/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHEAR WALL CORNERS NEED DBL STUDS - 2 PLCS ENTRY AND NE CORNER. 2. PROTECTION PLATE AT PLUMBING VENTS 3. NEED A-BOLT AT SPLICED PLATE LIVING ROOM WINDOW 4. NEED LET-IN BRACE NW EXT WALL 5. A.BOLT MISSING NUT AT PATIO SLIDER OPENING 6. CHECK SHEAR WALL PLAN FOR MISSING A.BOLTS 7. CLIP BEAM AT PATIO |