Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00493

Parcel: 141330060


Addresses:

8446 S HUNNIC DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00493

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/23/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/06/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS #3 & #7 FROM PREVIOUS INSPECTION
2) REFEE
03/27/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED RSP4 CLIP BOTTOM PLATE ENTRY
2) WEDGE BLOCKING AT 3 PT BEARING TRUSSES PATIO
3) NEED RETRO FOR H.D. AT REAR OF HOUSE
4) PROTECTION PLATE AT PLUMBING VENT SOUTHSIDE-2 PLACES
5) SHEAR PANEL NAILING SOUTH SIDE 4 X 8 PANEL
6) NO ACCESS TO ROOF
7) MISSING A.B. AT VARIOUS SHEAR PANELS PER SHEARWALL PLAN
8) NEED A LEDGEABLE SET OF TRUSS CALCS A02, A024 ARE FADED