Permit: T07CM00491

Parcel: 141330040


Addresses:

8430 S HUNNIC DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00491

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/22/2007 EXT METAL CLIPS/EXT SHEATHING Approved
03/27/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LET IN BRACNE NORTH SIDE 2 NAILS AT END INTO BOTTOM PLATE
2) WEDGE 3 PT BEARING TRUSSES AT PATIO
3) CHECK 4 X 8 PANEL FOR PROPER AMOUNT OF A.B. PER SHEARWALL PLAN SOUTH SIDE
4) NO LADDER TO ACCESS ROOF