Permit: T07CM00477

Parcel: 133351610


Addresses:

702 N BEDFORD DR

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/04/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
04/27/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
USE COPPER CONDENSATE WITHIN 6" OF FURNACE VENT
REPLACE FLATTENED TRAP
REPLACE 3/8" GAS FLEX
INSTALL DAMPER & INSULATE SLEEVE
04/13/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSULATE SHEETMETAL SLEEVES ON TOP OF COIL. SEAL ALL CONNECTIONS.
2. PROVIDE A TRAP ON PRIMARY DRAIN LINE. PVC CANNOT BE WITHIN 6" OF VENT CONNECTOR. PROVIDE AN OVERFLOW SENSOR ON SECONDARY OUTLET. PROVIDE HOSE CLAMPS ON PUMP & TRANSITION TO COPPER. CONNECT OVERFLOW SENSOR ON PUMP. CONNECT POWER TO PUMP.
3. 3/8" I.D X 12" GAS FLEX NOT ADEQUATE FOR 110,000 BTU
4. PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR.
5. SECURE WATER LINE IN CLOSET
6. VENT ON CONDENSATE DRAIN MUST BE DOWNSTREAM OF TRAP. TERMINATE CONDENSATE WITHIN 6" OF THE GROUND. NO SEWER VENTS.
7. PROVIDE A SEDIMENT TRAP ON GAS LINE AT FURNACE.
8. LOW VOLTAGE WIRE AT CONDENSOR MUST BE PROTECTED
USE CONDUIT
9. PROVIDE ROOF JACKS AT LINE SET PENETRATIONS.