Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/16/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) #2 BELOW NEED TRUSS DRAWINGS CHECK AT INTERMEDIATE |
|
| 03/13/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 18/SD3 AT EACH SIDE OF GARAGE SHEAR C820 X 36 SIMPSON STRAP 2) NEED TRUSS DRAWINGS FOR FRONT HIP AT GARAGE BEAM 3) P.T. CABLES HAVEN'T BEEN TENSIONED YET 4) ROOF TRUSSES TO GIRDER AT FRONT ALL HANGERS HUS-26 14 16D'S IN HEADER 5) REAR SHEAR NOT NAILED AT BOTTOM PLATE 6) DBL STUDS UNDER FRONT GIRDER CARRY DOWN LOAD TO FLOOR TO 1ST FLOOR 7) MISSING ROOF NAILING AT FRONT WEST BEDROOM, MARKED ON 2ND FLOOR DECK |