Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00451
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2007 | FRAMING | Approved | IVRS - Inspection :* | |
04/13/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STAIRWELL SHEAR WALL 4 CONNECTION TO TRUSS SYSTEM IS NOT PER 5/D-3 2. SHEAR WALL CONNECTION TO SECOND FLOOR NOT PER 12/D6 3. SEAL FLOOR PENETRATIONS AT TUBS & DUCTS 4. FURNACE SINGLE WALL VENT CONNECTOR CAN ONLY EXTEND 1 INCH INTO ATTIC SPACE. SEE FURNACE INSTALLATION MANUAL. 5. LATH NOT NAILED UNDER PORCH LEDGER |