Permit: T07CM00451

Parcel: 141096140

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/24/2007 FRAMING Approved IVRS - Inspection :*
04/13/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STAIRWELL SHEAR WALL 4 CONNECTION TO TRUSS SYSTEM IS NOT PER 5/D-3
2. SHEAR WALL CONNECTION TO SECOND FLOOR
NOT PER 12/D6
3. SEAL FLOOR PENETRATIONS AT TUBS & DUCTS
4. FURNACE SINGLE WALL VENT CONNECTOR CAN ONLY EXTEND 1 INCH INTO ATTIC SPACE. SEE FURNACE INSTALLATION MANUAL.
5. LATH NOT NAILED UNDER PORCH LEDGER