Permit: T07CM00450

Parcel: 141096110

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00450

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/27/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/14/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED RETRO AT REAR SHEARWALL PANEL SEE BELOW
2) WILL CHECK RETRO AT INTERMEDIATE
03/13/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED PROTECTION PLATE AT PLUMBING VENT SOUTH EXT. WALL BOTTOM PLATE AND REAR OF HOUSE
2) NEED RETRO FOR H.D. AT REAR SHEAR PANEL
3) NEED RSP4 CLIP AT S.E. CORNER OF PATIO WALL
4) DBL NAIL AT END OF LET IN BRACE EAST WALL AT GARAGE
5) REMOVE AND REPLACE BENT OVER NAILS AT GARAGE SHEARWALLS
6) GABLE END BRACING BOTH ENDS A35 NOT PER PLAN 2/D2
7) EDGE BLOCKING CALLS FOR 8D NOT STAPLES