Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00450
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/14/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED RETRO AT REAR SHEARWALL PANEL SEE BELOW 2) WILL CHECK RETRO AT INTERMEDIATE |
|
03/13/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PROTECTION PLATE AT PLUMBING VENT SOUTH EXT. WALL BOTTOM PLATE AND REAR OF HOUSE 2) NEED RETRO FOR H.D. AT REAR SHEAR PANEL 3) NEED RSP4 CLIP AT S.E. CORNER OF PATIO WALL 4) DBL NAIL AT END OF LET IN BRACE EAST WALL AT GARAGE 5) REMOVE AND REPLACE BENT OVER NAILS AT GARAGE SHEARWALLS 6) GABLE END BRACING BOTH ENDS A35 NOT PER PLAN 2/D2 7) EDGE BLOCKING CALLS FOR 8D NOT STAPLES |