Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM00428

Parcel: 116230520


Addresses:

828 W 19TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/15/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) PENDING AT INTERMEDIATES
08/14/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
08/13/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWNS HAVE NO STRUCTURAL VALVE DUE TO SPAULDING. WILL NEED ENGINEERED RETRO
2) PLANS CALL FOR 4 X 8 BEAM AT ENTRY ARCH
3) GABLE END BLOCK CALLS FOR 2 X 6 PER 2/SD2
4) GARAGE OPENING NEEDS TO BE BUILT PER 11/SD3
5) RSP4 CLIPS GABLE ENDS NOT CONNECTING TRUSS TO TOP PLATE
6) NEED PROTECTION PLATE AT PLUMBING VENT AT KITCHEN WINDOW
7) STOPPED INSPECTION
8) READ DETAILS ON YOUR DRAWINGS