Permit: T07CM00416

Parcel: 141312930

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00416

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/15/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/14/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) SEE LAST INSPECTION
03/13/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) HGU528 HANGERS NOT INSTALLED
03/09/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. AT DBL. GIRDERS, PLAN CALLS FOR HGUS28, HGUS26 INSTALLED DINING ROOM
2. ALSO, A-16 TRUSS IS NOT 3PT BEARING DON'T SHIM AT SHEAR WALL MSTR. BED
3. A-22 GETS A RAT RUN
4. A26-A27 ARE 3PT BEARING (SHIM AT INTERIOR)
5. NAIL & BLK ALL OSB AT 4'0" EDGE, NAIL ALL BLK MARKS ON ROOF.