Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM00395
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
06/26/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) NEED DBL STAMP FROM ENGINEER |
|
06/25/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SET SCREW NEEDED IN BACK VACUUM BREAKER ON HOSE BIB 2) UNION NEEDED AT PRV LINE FOR WATER HEATER IRC P2801.3 3) GAS TAG GIVEN |
|
06/21/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANTI TIP DEVICE ON STOVE 2) SET SCREWS NEEDED IN ANTI SIPHON AT HOSE BIBS 3) CANNOT CONNECT 2 FLEXABLE CONNECTORS AT FURNACE |
|
06/20/2007 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* |