Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00393
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/14/2007 | FRAMING | Approved | IVRS - Inspection :* | |
05/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE TWISTED STUD AT MASTER CLOSET 2) NOT COMPLETED 2ND FLOOR 3) BLOCK MECHANICAL DUCT VENT 3 SIDES UPSTAIRS BEDROOM 4) NEED TO SEAL ALL CUT OUTS AND FINISH WIRE MESH 5) SEAL ALL PENETRATIONS IN VAPOR BARRIER 6) NEED PROTECTION PLATE AT BATH #4 TRAP ARM 7) DWV AND WATER OK |
|
04/18/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |