Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00390
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2007 | FRAMING | Approved | IVRS - Inspection :* | |
04/23/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PORCH DRYWALL BLOCK EVERY 2' 2) RESOLVE ISSUE OF WATER HEATER PLATFORM 3) SECURE WEST SIDE OF LANDING 4) SHEARWALL 4 REQUIRES ANCHOR BOLTS 24" ON CENTER 5) REPAIR TOP PLATE AT WASHING MACHINE 6) WIRE EXHAUST FAN OVER MASTER TUB/SHOWER 7) BRACE 4 GANG BOX SGD AND FRONT DOOR 8) AT FINAL, AAV REQUIRED LAV NORTH BATHROOM |
|
03/29/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |