Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00390
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
03/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) NEED 1ST FLOOR AND 2ND FLOOR STRAPS CS20 48" ON CENTER-4 NAILS IN EACH STUD TOP/BOT 2) RAT RUNS ON GABLE ENDS AND SIX B-1 TRUSSES EACH SIDE 3 RAT RUNS ON EACH TRUSS 3) TRY TO LOCATE SHEAR TRANSFER DETAIL PARALLEL SIDES 4) REAR PORCH NEEDS FLASHING BACKING |