Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00387

Parcel: 141353470


Addresses:

6011 S JAKEMP TR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM00387

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/19/2007 FRAMING Approved IVRS - Inspection :*
04/18/2007 FRAMING Partial Approval IVRS - Inspection :*
1) NO PLANS ON SITE
2) TIGHTEN RED HEADS WITH WRENCH
3) SHIM FLOOR TRUSSES AT BEAM N OF KITCHEN
4) CONNECT UFER TO REBAR
5) NO PRESSURE ON SUPPLY LINES
6) NO DWV TEST
7) SUPPORT ABS EVER 4'
8) ABS UNDER STAIRS OUT OF WALL
9) VENT FOR MASTER TOILET ?
10) SUPPLY AIR TO KITCHEN ?
03/29/2007 FRAMING Not ready for Inspection IVRS - Inspection :*