Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00372
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/09/2007 | FRAMING | Approved | IVRS - Inspection :* | |
05/08/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PER DETAIL 303, NEED 3/8 PLY OR OSB ON BLOCKING BETWEEN FLOOR TRUSSES AT INTERIOR 2) STUCCO MESH-BEARING WALLS 3) LEAK IN TUB DRAIN OVER LIVING ROOM 4) NO TUB IN GUEST BATH |
|
05/07/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE TITEN BOLT KITCHEN 2) COMPLETE STUCCO LATH FOR INTERMEDIATES 3) NO SMOKIE S.W. BEDROOM 4) NEED FLOOR OUTLET NEAR STAIRS 5) SECURE 4 GANG BOX NEAR STAVES 6) 12" PEX TO CAN LIGHT KITCHEN 7) NO TUB GUEST BATH |
|
04/18/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
04/17/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) ADD RETRO H.D.'S N.E. CORNER GARAGE 2) NAIL SHEAR TO ALL STUDS |