Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00371
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
03/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) STRAP 48" ON CENTER 1ST FLOOR 2ND FLOOR CS20 STRAP 4 NAILS IN TOP AND BOTTOM STUDS 2) RAT RUNS ON GABLE PLUS B-1 TRUSSES SIX EACH SIDE 3 BRACES ON EACH TRUSS 3) CANNOT LOCATE PARALELL SHEAR TRANSFER TO DRAG TRUSSES ROOF ? 4) FLASHING BACKING REAR PORCH |