Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00370
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/08/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/07/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK SHEAR SEAMS OR SUPLY ENGINEERING FOR REFIDGE SUPPLY 2) BANG PLATE AND NAILS IN FHA STRAPS |
|
06/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED MINIMUM 10 POUNDS FOR GAS LINE TEST/LOSING PRESSURE 2) SHEARWALL CUT AT KITCHEN H.D., BLK AND REPLACE OSB 3) TRUSS REPAIR FLOOR TRUSSES (TWO) AT STAIR 4) 1ST FLOOR BATH, PEX LINES TO BE 12" FROM LIGHT CAN 5) DUCT IN HALL NOT SECURED 6) CONDENSATE LINES NOT COMPLETE 7) STAPLES IN SOIL AND POTABLE H20 2ND FLOOR NORTH BATHROOM 8) NEED APPROVAL TO USE TITEN TAP/CON BOLTS AT H.D.'S 9) NEED HUS26 HANGER AT ROOF GIRDER |