Permit: T07CM00370

Parcel: 141350120

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM00370

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/08/2007 FRAMING Approved IVRS - Inspection :*
06/07/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK SHEAR SEAMS OR SUPLY ENGINEERING FOR REFIDGE SUPPLY
2) BANG PLATE AND NAILS IN FHA STRAPS
06/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED MINIMUM 10 POUNDS FOR GAS LINE TEST/LOSING PRESSURE
2) SHEARWALL CUT AT KITCHEN H.D., BLK AND REPLACE OSB
3) TRUSS REPAIR FLOOR TRUSSES (TWO) AT STAIR
4) 1ST FLOOR BATH, PEX LINES TO BE 12" FROM LIGHT CAN
5) DUCT IN HALL NOT SECURED
6) CONDENSATE LINES NOT COMPLETE
7) STAPLES IN SOIL AND POTABLE H20 2ND FLOOR NORTH BATHROOM
8) NEED APPROVAL TO USE TITEN TAP/CON BOLTS AT H.D.'S
9) NEED HUS26 HANGER AT ROOF GIRDER