Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM00363

Parcel: 13204271A


Addresses:

3285 E 44TH ST

Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Date Description Inspector Results Comments
08/06/2007 STEM WALL/RETAINING WALL Approved IVRS - Inspection :*
05/01/2007 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS STEM WALL/RETAINING WALL
STEM WALL WITH 2 #4 ON THE BOTTOM OF STEM PLUS 2 #4 ON TOP HORIZONTALS, #5 @ 8" O.C AND #5 @ 32" O.C
FOR MASONRY WALL ABOVE STEM PLUS REINFORCING FOR MCJ