Permit: T07CM00354

Parcel: 123040560


Addresses:

2906 E LINDEN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/29/2008 FRAMING Approved
05/04/2007 FRAMING Partial Approval IVRS - Inspection :*
1) ADDITON ONLY
2) ROOF TOP UNIT NOT ON PLAN-SUBMIT AS BUILT
3) INSTALL SMOKIES IN EXISTING HALL AND BEDROOMS
05/02/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING SMOKIE FAMILY ROOM
2) HARD WIRE SMOKIES TO EXISTING BEDROOMS AND HALL IS ?
3) FIREBLOCK ?
4) SUPPORT RIDGE BEAM EAST
5) TERMINATE EXHAUST FAN TO EXTERIOR
04/30/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MINIMUM WIDTH WINDOW IN BEDROOM TO MAKE EGRESS OF 20"
2) SUPPORT RIDGE BEAM
3) NAIL PROTECTION ON WIRES OF FURRED OUT WALL IN GARAGE
4) SMOKE DETECTOR NEEDED IN BEDROOM
5) 12/2 DEDICATED CIRCUIT FOR BATHROOM GFI
6) HOOK UP BATH FAN
04/24/2007 FRAMING Partial Approval IVRS - Inspection :*
1) INSTALL LATHE
2) OK TO COVER EXTERIOR OSB PER HOUSE BILL 2254 BLUE TRACER WIRE
04/13/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
FOR EXTERIOR ONLY

1. WATER SHALL DRAIN AWAY FROM WALL IN FRONT CONC. SHALL SLOPE AWAY FROM WALL.
03/29/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK ALL OSB NAILING
2) BLOCK AND NAIL BRACED PANEL JOINTS 6" ON CENTER EDGES 12" FIELD
3) EXTERIOR SHEATHING INSPECTION ONLY