Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2008 | FRAMING | Approved | ||
| 05/04/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ADDITON ONLY 2) ROOF TOP UNIT NOT ON PLAN-SUBMIT AS BUILT 3) INSTALL SMOKIES IN EXISTING HALL AND BEDROOMS |
|
| 05/02/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING SMOKIE FAMILY ROOM 2) HARD WIRE SMOKIES TO EXISTING BEDROOMS AND HALL IS ? 3) FIREBLOCK ? 4) SUPPORT RIDGE BEAM EAST 5) TERMINATE EXHAUST FAN TO EXTERIOR |
|
| 04/30/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MINIMUM WIDTH WINDOW IN BEDROOM TO MAKE EGRESS OF 20" 2) SUPPORT RIDGE BEAM 3) NAIL PROTECTION ON WIRES OF FURRED OUT WALL IN GARAGE 4) SMOKE DETECTOR NEEDED IN BEDROOM 5) 12/2 DEDICATED CIRCUIT FOR BATHROOM GFI 6) HOOK UP BATH FAN |
|
| 04/24/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) INSTALL LATHE 2) OK TO COVER EXTERIOR OSB PER HOUSE BILL 2254 BLUE TRACER WIRE |
|
| 04/13/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* FOR EXTERIOR ONLY 1. WATER SHALL DRAIN AWAY FROM WALL IN FRONT CONC. SHALL SLOPE AWAY FROM WALL. |
|
| 03/29/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK ALL OSB NAILING 2) BLOCK AND NAIL BRACED PANEL JOINTS 6" ON CENTER EDGES 12" FIELD 3) EXTERIOR SHEATHING INSPECTION ONLY |