Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM00318

Parcel: 127051810


Addresses:

4865 E 3RD ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/29/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/21/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSED ROWS OF NAILING AT SOUTH AND NORTH WALLS
2) ROOF NAILING MISSED ON OVERHANG AND AT BIRD BOARDS
3) SHIM HEADER/PLATE AND STUD/PLATE CONNECTIONS