Permit: T07CM00311

Parcel: 11106055B

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
06/12/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) WRAP COPPER AT STUCCO PENETRATIONS
06/08/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE WATER TEST ON DWV THRU ROOF
- 1/4" PER FOOT SLOPE ON TRAP ARMS
- HORIZONTAL CHANGES OF DIRECTION REQUIRE SWEEPS
- 18" OF METALLIC TUBING IS REQUIRED WHERE FUTURE SWEAT CONNECTIONS MAY EXIST.
- PROTECT COPPER FROM STUCCO.
- INSTALL CLOSET FLANGES PER UPC SECTIONS 704.4.4, 316.3.1 AND IS #5 SEC. 314.2 ON PG 320