Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/12/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* SEE CORRECTIONS FOR #3, #4, #5, #6 OTHER ITEMS OK |
|
| 09/07/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CORRECTIONS FROM PREVIOUS INSPECTIONS HAVE NOT BEEN COMPLETED -- YOU WILL NEED TO PAY A REINSPECTION FEE. PLEASE DO NOT CALL FOR FINAL BEFORE FEE IS PAID AND CORRECTIONS MADE. |
|
| 09/06/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR NORTH UNIT WAITED OVER 1HR -- BORRIS DID NOT SHOW 1. SMOKE DETECTORS NOT INTER-CONNECTED 2. SMOKE DETECTOR IN HALL TO CLOSE TO CEILING 3. MISSING KITCHEN COUNTER RECEPTACLE NEXT TO RANGE (WITHIN 24") 4. MISSING RECEPTACLE IN LIVING ROOM (WITHIN 6' OF BROKEN WALL LINE) 5. MISSING BEDROOM RECEPTACLE BY DOOR ALSO, SEE CORRECTIONS FROM PREVIOUS INSPECTION FOR THIS UNIT 6. KITCHEN COUNTER RECEPTACLE IN SOUTH UNIT TO BE ABOVE COUNTER, NOT BEHIND RANGE. PARTIAL INSPECTION -- PROVIDE ROOF ACCESS |
|
| 09/05/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GROUND ALL SWITCHES WITH EQUIPMENT GROUND TIGHTEN AND DO NOT OVERLAP GROUND ON GROUND SCREW 2. BEDROOM LIGHTS AND SMOKE DETECTORS REQUIRE ARC FAULT PROTECTION 3. INSTALL RANGES 4. INSTALL ALL LIGHT BULBS AND OR MAKE SURE ALL FIXTURES ARE WORKING 5. NEED #10CU GROUND TO WATER HEATER 6. FRONT ENTRY LIGHT NOT WORKING 7. PANEL DIRECTORY TO BE CORRECT, NEAT AND LEGIBLE 8. PROVIDE AN ACCEPTABLE LADDER FOR ROOFTOP INSPECTION 9. PROVIDE DISCONNECTING MEANS FOR HOT WATER TANK PARTIAL INSPECTION SOUTH UNIT -- CHECK SAME CORRECTIONS OTHER UNIT |