Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/19/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/15/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO COMPLETE ALL CORRECTIONS FROM PREVIOUS INSPECTION 2) IF ITEMS ARE NOT COMPLETE NEXT INSPECTION, A FEE MAY BE CHARGED |
|
| 06/14/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED NAIL PLATE NEC 300.4 2) HAVE OVER FILLED BOXES NEC 314.16 3) USE PROPER CRIMP TOOL ON CRIMP SLEEVES NEC 110.3 (B) 4) SMOKE DETECTORS TO BE 36" AWAY MIN. FROM HVAC VENT NFPA 72 5) SCREWS NOT ALLOWED ON INSIDE OF BOXES NEC .23 B1 6) KITCHEN COUNTER CKTS AND DISPOSAL SHARED ? CHECK KITCHEN MAKE UP 7) GROUND ALL METAL BOXES NEC 250.148 8) CHECK RECEPTACLE SPACING NEC 210.52 9) CHECK SMOKE DETECTOR MOUNTING SHOULD BE WITHIN 12" OF CEILING NEC 110.3 B 10) HAVE ELECTRICIAN ON SITE FOR INSPECTION |