Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00306
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/01/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK MECH 1ST FLOOR 2) 42" UNIT LAV TRAP ARM 2ND FLOOR 3) BANG PLATE BACK SIDE GARAGE UTL. SINK AT BOTTOM PLATE 4) CHECK FOR NAILS IN 3" STACKS LAUNDRY 5) NEXT TO REFRIDGERATOR NAIL STUDS TO OSB AT H.D. 6) COLD SIDE H20 LINES NICKED AT KITCHEN SINK 7) PLEASE PULL STAPLE LATH OUT AT BOTTOM PLATE AT H20 SERVICE 8) PT LOAD, GLU LAM AT STAIR BRING DOWN TO FLOOR 9) NAIL IN VENT 2ND FLOOR BATHROOM 10) OVERSPAN STUD AT SHOWER 11) ALL 2ND FLOOR, SHEAR BOTTOM PLATES 3-16D AT 16" ON CENTER-INCLUDE DRYWALL SHEAR 12) NOTE: DO NOT INSTALL WEDGE A.B. AT EXT. SHEARWALLS, TO BE EPOXY ONLY 13) MISSED A.B. FRONT BATHROOM 1ST FLOOR |