Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00306
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) GARAGE FRONT SHEAR 3"-12" 2) NAIL IN H20 LINE KIT SINK 3) PUT BANG PLATE ON ISLAND CONDUIT REAR WALL 4) MISSING WIND BRACE SOUTH WALL 2ND FLOOR 5) SHEAR TRANSFER 1ST FLOOR FRONT BATHROOM 6) REPAIR SHEAR AT H20 SERV. SHEAR TRANSFER ABOVE 7) MISSING WIND BRACE 2ND FLOOR, TWO NAILS IN ALL WIND BRACES AT TOP/BOTTOM PLATES 8) INSTALL CS 16 STRAP 5-0" LONG FRONT TRUSS AT ROOF ABOVE GARAGE TO TRUSS AT LIVING ROOM (JOINT) ON ROOF FRAME PLAN 9) NAIL ALL VERTICAL STUDS ATTACHED TO P.A.'S 10) CHECK NAIL SIZE TRUSS TO GIRDER 2ND FLOOR 11) COIL STRAP 1ST & 2ND FLOOR ENTRY OUTHER STUD 12) NAIL ROOF SHEATHING TO BLOCKS AT BEARING PT VAULTED LIVING ROOM 89A/SD3 13) NAIL SHEAR TO TRUSS BOTTOM CHORD 2ND FLOOR FRONT BEDROOM |
|
| 03/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied |