Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00305
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/02/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OVER NOTCHED STUD MASTER BATH (DIVERTER VALVE) 2) FIRE/BLK DUCT BEHIND DIVERTER VALVE 3) OVERSPAN STUD SPACE PANTRY 4) MASTER CAN LIGHT PEX TO CLOSE 5) MASTER BED/BATH TRUSSES AREN'T 3 PT BEARING-REMOVE SHIMS 6) HALL BATH VENT NOT SECURED AT ROOF 7) OVERSPAN STUD NEXT TO TUB AND LAUNDRY 8) WRONG SIZE NAILS IN HTT AT LIVING ROOM |