Permit: T07CM00297

Parcel: 141316790


Addresses:

7772 E JACK OAK RD


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00297

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/24/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/22/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
05/18/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
05/11/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK/NAIL OSB GARAGE HIP EDGE
2) 2 NAILS IN ALL WIND BRACES AT PLATES
3) NAIL OSB EDGE TO LEDGER GARAGE
4) SECURE 207 HIP TRUSS AT FRONT ENTRY
5) HANGERS MISSING ALL HIP JOINTS
6) PLYWOOD/OSB ROOF DECK, 6"/12" WITH 8D'S STAPLES 3"-6"
7) REAR TRUSS X BRACES NOT SECURED