Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00297
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/18/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK/NAIL OSB GARAGE HIP EDGE 2) 2 NAILS IN ALL WIND BRACES AT PLATES 3) NAIL OSB EDGE TO LEDGER GARAGE 4) SECURE 207 HIP TRUSS AT FRONT ENTRY 5) HANGERS MISSING ALL HIP JOINTS 6) PLYWOOD/OSB ROOF DECK, 6"/12" WITH 8D'S STAPLES 3"-6" 7) REAR TRUSS X BRACES NOT SECURED |