Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00293
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H.D.'S NOT COMPLETE 2) LEAKING H20 AT SERVICE 3) DIVERTER STUD NOTCHED TO DEEP 4) NEED CURRENT TRUSS DRAWINGS, ATTACH PER DRAWING TO WALL (HANGER, OR TOP CHORD BEARING) 5) CHECK 90 DEGREE FITTINGS AT 2ND FLOOR TO FIRST FLOOR 6) BUSHING SECURE ROMEX A.C. UNIT TO EXT 7) STIFF LEG FLAT 2 X 4 CEILING JOIST BATHROOM 8) PEX TO CAN 1ST FLOOR HALL WAY 9) DWV OK 10) BLK A.C. LINES AT EXT. WALL |
|
| 05/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/18/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SLOPED HANGER AT LIVING ROOM 2) LS210-INSTALLED, NOT PER PLAN 3) LUS26, OR JUS26 ARE PRESCRIBED PER PLAN BUT THE VERTICAL MEMBERS OF THE TRUSSES IS SPLITTING |
|
| 05/08/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) LEDGERS REQUIRE 4 16D EACH STUD A3.5 EVERY OTHER, TAP NOT BENT OVER ADD H2.5 AT A3.5 TIE LEDGER TO WALL 16D ? 2) SHIM REAR 2ND GABLE CONTINOUS BEARING 3) 2ND FLOOR SHEAR 16/SD2 4) 821 POUNDS CLEAR STORY TRUSS NEED HANGER TYPE |