Permit: T07CM00293

Parcel: 141314000

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00293

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/11/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/07/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H.D.'S NOT COMPLETE
2) LEAKING H20 AT SERVICE
3) DIVERTER STUD NOTCHED TO DEEP
4) NEED CURRENT TRUSS DRAWINGS, ATTACH PER DRAWING TO WALL (HANGER, OR TOP CHORD BEARING)
5) CHECK 90 DEGREE FITTINGS AT 2ND FLOOR TO FIRST FLOOR
6) BUSHING SECURE ROMEX A.C. UNIT TO EXT
7) STIFF LEG FLAT 2 X 4 CEILING JOIST BATHROOM
8) PEX TO CAN 1ST FLOOR HALL WAY
9) DWV OK
10) BLK A.C. LINES AT EXT. WALL
05/22/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
05/18/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) SLOPED HANGER AT LIVING ROOM
2) LS210-INSTALLED, NOT PER PLAN
3) LUS26, OR JUS26 ARE PRESCRIBED PER PLAN BUT THE VERTICAL MEMBERS OF THE TRUSSES IS SPLITTING
05/08/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) LEDGERS REQUIRE 4 16D EACH STUD A3.5 EVERY OTHER, TAP NOT BENT OVER ADD H2.5 AT A3.5 TIE LEDGER TO WALL 16D ?
2) SHIM REAR 2ND GABLE CONTINOUS BEARING
3) 2ND FLOOR SHEAR 16/SD2
4) 821 POUNDS CLEAR STORY TRUSS NEED HANGER TYPE