Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM00245
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2008 | PLUMBING - INTERMEDIATE | Approved | ||
10/11/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER WALLS NEED TO SEE SHOWER LINER TEST |
|
10/10/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SHOWER PANS TO BE INSTALLED PER 412.8 2003 UPC AT 411.8 2006 UPC MAYBE I ERRED ON LOTS #1 AND #5 THINK WE SHOULD TAKE ANOTHER LOOK? |
|
10/02/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* VERTICAL PVC TO BE SUPPORTED STRAPPING REQUIRED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE ENDS OF BRANCHES - NO MORE THAN 4' BETWEEN HANGERS. NEED TO SEE SHOWER PANS SECURE CLOSET FLANGES LIST MAY NOT BE COMPLETE |