Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM00220
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/17/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER WALLS EXCEPT AT SOFT WATER SUPPLY TO WH PIPING WITHIN STUD AND CLOSER THAN 1 1/4" TO STUD FACE MAYBE DAMAGED BY SHEETROCK SCREWS. ALSO, RECIRC LINE IS TOUCHING SPRINKLER SADDLE. REROUTE LINES TO CLEAR. DO A NICER JOB TAPING INSULATION ABV CEILING, TAPE APPEARS TO BE PEELING OFF. RECALL 03035 AND 03036 INSPECTIONS. |
|
04/16/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |