Permit: T07CM00215

Parcel: 141091500


Addresses:

8059 S TALACO TR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00215

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/21/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/18/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILING ON SHEARWALL #5 NOT COMPLETE
2) NEED NAILS #4 ON CENTER AT EDGGES WHERE NOTCHED FOR GLU LAM AND INSIDE FURRED OUT BEAM
05/16/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/PERMIT ON SITE
2) NO PRIOR INSPECTION REPORT ON SITE
05/11/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REAR #5 SHEARWALL NOT NAILED AT 4" ON CENTER ENDS AND EDGES ABOVE 8 FT SEAM
2) #5 SHEAR SHEATHING MUST EXTEND TO TRUSS SYSTEM AT S.E. CORNER. BLOCK EDGE ADD SHEATHING
3) MISSING STUD BY KITCHEN WINDOW