Permit: T07CM00198

Parcel: 12701004C

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07CM00198

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/17/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/09/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) INTERMEDIATE OK FOR ROOMS #110, #111 AND #112
03/22/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. BELOW FLOOR CLOSET BENDS AND CAPS OK
2. INSTALL SWEEPS ON TRAP ARM CHANGES OF DIRECTION.
3. INSULATE HW
4. PROVIDE ACCESS TO BOTH SHUT OFF VALVES LOCATED IN PLUMBING CHASE.
5. SECURE VENT ON LAVITORY WALLS
6. SAFETY PLATE ALL PIPING WITHIN 1 1/4" OF STUD FACE
7. SUPPORT OVERHEAD CU TO SHOWER AT 6' INTERVALS
8. AT P.5 USE MISSION COUPLINGS.
9. SUPPORT CAST IRON IN EXISTING TOILET ROOMS
10. REDLINE CHANGES ON PLAN
I.E FIXTURE REPLACED AT EXISTING ALSO, CW TO SHOWER
03/09/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER WASTE & VENT W/TEST TO ABV CEILING GRID 1ST FL
CAP ALL OPEN SEWER PIPES TO PROTECT WORKERS
MIKE W/BESTWAY