Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE. PLEASE PROVIDE AN ELBOW AT END OF CONDENSATE DRAIN, CLAMP PIPE TO WALL & PAINT W/LATEX PAINT. PLUMBING INSPECTOR WILL CHECK WHEN HE COMES OUT. |
|
| 02/28/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE ALL DUCT TAPE FROM EXPOSED DUCT & USE ONLY DUCT SEALANT. SEAL THE GORES ON THE 90 DEG. ELBOWS ALSO. 2. DO NOT USE WHITE WIRE IN THE DISCONNECT OR THE CIRCUIT PANEL TO POWER THE UNIT. TAPE ALL ENDS WITH BLACK TAPE. 3. USE ONLY A SIEMENS BREAKER IN THE ELEC. PANEL RECALL FOR INSPECTION |