Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/26/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SEE NOTES FORM 12/20/07-VENT TO BE CONNECTED DOWNSTREAM OF FIXTURE TRAP |
|
| 12/24/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) DOOR LOCKED |
|
| 12/20/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. EACH FIXTURE TRAP REQUIRES A CORRECTING VENT DOWNSTREAM AS SHOWN ON DETAIL #5 P2.1 WASTE ISOMETRIC 2. AT STORAGE AND CHEM STORAGE, ARCHITECT ALLOWS 2 SINKS DUMPING INTO ONE SUMP. HOWEVER, THE MINIMUM WASTE SIZE FOR A SINK IS 2" AND EACH FIXTURE TRAP NEEDS TO BE VENTED. 3. CHECK ALL OTHER SINK LOCATIONS FOR VENTS AND BACKPITCH. |
|
| 12/18/2007 | PLUMBING - FINAL | Not ready for Inspection | 1. 3/4" VALVE INSTALLED ON A ONE INCH LINE (AT RPPBP) NOT PER CODE 2. SK-3'S AT STORAGE 116 AND CHEM STORAGE 115 NOT INSTALLED PER PLAN. NO REDLINES SHOWING CHANGE, 1001.2 SINKS SET ADJACENT TO, OR SIDE BY SIDE, IN THE SAME ROOM MAY SERVE A SINGLE TRAP. 3. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
| 12/12/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* EACH AND EVERY ITEM ON THE PLAN NEEDS TO BE ADDRESSED. EITHER INSTALL IT PER PLAN OR REVISE THE PLAN. CONTRACTOR SHALL PAY REINSPECTION FEE. |
|
| 12/06/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SEE PLUMBING INSPECTION NOTE #3 FROM 7/12/07 STILL NO REDLINES EACH AND EVERY ITEM ON THE APPROVED PLAN TO BE ADDRESSED, OR PROVIDE A REVISED PLAN 2. SEE PLUMBING PLAN NOTES #19 & #31 PO.1 INSULATION TO BE CONTINUOUS 3. SEE CORRECTION NUMBER 4 FROM 11/15/07 4. YOU MAY WANT TO REVIEW 710.4 & 710.9 2006 UPC |
|
| 11/15/2007 | PLUMBING - FINAL | Denied | - WH PIPING NOT SIZED PER DETAIL - ALSO, INSULATE PIPING - CONDENSATE CONNECTION NOT PER DETAIL - SUMP DISCHARGE MISSING UNION & CHECK VALVE RECOMMENDED - IN INSTALLATION MANUAL, ALSO, TEF TAPE SPECIFIED FOR CONNECTION - LAV CARRIER NOT INSTALLED PER SPEC - ABV CEILING NOT YET APPROVED |