Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* DOOR LOCKED CONTINUED "NOT READY" WILL RESULT IN RE-INSPECTION FEE. WENT AROUND BACK AND FOUND THE PLUMBERS UNDERGROUND PLUMBING OK TO COVER PROVIDE LISTINF FOR CLOSET FLANGE |
|
| 07/12/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. POST YOUR SUITE NUMBER 2. ALL OPEN PIPING CONNECTED TO A SANITARY SEWER TO REMAIN CAPPED AT ALL TIMES. 3. ANY AND ALL CHANGES TO THE PLAN MUST BE ACCOMPANIED WITH REDLINES AT THE TIME OF INSPECTION 4. I WANT TO SEE ALL VACUUM PIPING 5. EXISTING CONDENSATE DRAINS TIED DIRECTLY INTO VENTS ABOVE CEILING ARE NOT APPROVED, CREATE AN UNSANITARY CONDITION AND ARE TO BE RE-ROUTED 6. ALL DWV PIPING BELOW GRADE TO HAVE 2% PITCH 7. ALL DEMO'D PIPING TO BE INSPECTED BEFORE COVERING |