Permit: T07CM00178

Parcel: 11008305F


Addresses:

2485 N SWAN RD #161


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07CM00178

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/05/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
06/04/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. DOUBLE CHECK REQUIRED AT NON-CARBONATED BEVERAGES. TEST REQUIRED.
2. PROPERLY INSTALL PVC DRAIN FROM SODA
I.E SUPPORT, ROUTING AND PRIMER
3. CORRECT SLOPE AT 3-COMP SINK
4. INDIRECT DRAINS REQUIRE CLEANOUTS AND WYE PATTERN FITTINGS.
5. SEPARATE CONDENSATE FROM ICE BIN DRAIN, SUPPORT PIPING.
6. CORRECT SLOPE AT T & P
7. PROVIDE BACKFLOW PROTECTION FOR OR ELIMINATE SECOND ICE MACHINE SUPPLY
8. PAINT EXPOSED PLASTIC VENT TERMINATIONS.
06/01/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
HOOK UP ALL EQUIPMENT
MAKE ALL CONNECTIONS
INSTALL ALL PIPING, BEFORE CALLING FINAL
05/31/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PAT @ 409-1156
05/30/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CLOSET FLANGES ARE OK
05/29/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*